Tested per standard. Proven per sample.
CASTOVELLA casters are built to the ISO 22883 and EN 12527–12532 specification and test framework, with load performance verified per EN 12532 / ANSI ICWM conventions — on the sample, before your bulk order exists.
A note on language first, because this industry abuses it: ISO 22883 and the EN 12527–12532 series are specification and test-method standards for casters and wheels — they define dimensions, requirements and how performance is tested. ANSI ICWM standards do the same work in the US market. When we say a caster is built to and tested per these standards, that is a statement about the framework its specification follows and the methods its sample was tested by. It is not a certification claim, and you should be suspicious of any caster supplier who presents test-method standards as certificates.
The sample protocol
- Dimensional verification. Wheel diameter and wheel width measured (width is both a performance and a tariff variable), overall height, plate pattern or stem dimensions checked against the locked specification.
- Material verification. Tread hardness measured against the stated Shore range; stainless grade confirmed per component on the stainless line; core and fork materials checked against the specification.
- Component verification. Bearing type confirmed as specified; fork and top plate thickness measured in millimetres; brake operation tested where fitted.
- Load testing. Dynamic and static load performance tested per the stated convention (EN 12532 / ANSI ICWM), at the rating the quotation claims — including, for the high temperature line, bake testing of the assembled caster before any temperature rating is stated.
- Approval and retention. The approved sample is the reference standard for the order; bulk production is checked against it.
Batch traceability
Each production order carries batch identification that ties the shipment back to its production run and its approved sample. If a question arrives with a shipment — a dimension, a hardness reading, a field failure — it is answered against records, not recollections. Buyers running private label programmes (see OEM) receive the batch references with their order documentation.
What we do not do
- We do not display other companies' test reports or certificates as if they were ours.
- We do not publish performance figures — temperature ratings, capacities — that have not been produced by testing the actual configuration being sold.
- We do not substitute materials or components against a locked specification without raising it before shipment.
Ratings you can ask questions about.
Every number on a CASTOVELLA quotation has a method behind it. Ask — we answer with the method.